ATXL25J2V1B / ARXL25M2V1B ATXL35J2V1B / ARXL35M2V1B
Poff (Off mode) W 1.0 1.0
Cooling Psb (Standby mode cooling) W 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25
Seasonal efficiency (according to EN14825) Cooling Pdesign kW 2.50 3.50
    Annual energy consumption kWh 146 209
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.01 5.87
    D Condition (20°C - 27/19) Pdc kW 2.17 2.17
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.30 10.15
    C Condition (25°C - 27/19) Pdc kW 2.02 2.02
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.52 7.37
    A Condition (35°C - 27/19) Pdc kW 2.50 3.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.12 3.07
    B Condition (30°C - 27/19) Pdc kW 1.84 2.58
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.02 4.91
  Heating (Average climate) Annual energy consumption kWh 799 998
    Pdesign kW 2.50 3.00
    Required back up heating cap at design conditions kW 0.00 0.00
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+ A+
    TBivalent Pdh (declared heating cap) kW 2.50 3.00
      Tbiv (bivalent temperature) °C -10 -10
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.03 2.27
    C Condition (7°C) Pdh (declared heating cap) kW 1.28 1.28
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.33 5.33
    TOL Tol (temperature operating limit) °C -25 -25
      Pdh (declared heating cap) kW 1.76 2.02
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.49 2.11
    A Condition (-7°C) Pdh (declared heating cap) kW 2.21 2.65
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.35 3.15
    D Condition (12°C) Pdh (declared heating cap) kW 1.32 1.32
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 5.50 5.50
    B Condition (2°C) Pdh (declared heating cap) kW 1.35 1.62
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.66 4.39
  Heating (Cold climate) Annual energy consumption kWh 1,944 2,691
    Pdesignh kW 3.60 4.40
    Required back up heating cap at design conditions kW 1.00 1.30
    Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-Seasonal efficiency according to en14825 heating cold climate energy efficiency class 3.60 3.43
    D Condition (12°C) Pdh (declared heating cap) kW 1.32 1.32
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-D Condition (12°C)-=-Copd declared cop 5.50 5.50
    TBivalent Tbiv (bivalent temperature) °C -15 -15
      Pdh (declared heating cap) kW 2.98 3.58
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-TBivalent-=-Copd declared cop 2.85 1.79
    TOL Tol (temperature operating limit) °C -25 -25
      Pdh (declared heating cap) kW 1.76 2.02
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-TOL-=-Copd declared cop 2.49 2.11
    C Condition (7°C) Pdh (declared heating cap) kW 1.28 1.28
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-C Condition (7°C)-=-Copd declared cop 5.33 5.33
    A Condition (-15°C) Pdh (declared heating cap) kW 2.98 3.58
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-A Condition (-15°C)-=-Copd declared cop 2.85 1.79
    A Condition (-7°C) Pdh (declared heating cap) kW 2.21 2.65
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-A Condition (-7°C)-=-Copd declared cop 3.35 3.15
    B Condition (2°C) Pdh (declared heating cap) kW 1.35 1.62
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-B Condition (2°C)-=-Copd declared cop 4.66 4.39
Cooling capacity Nom. Btu/h 8,530 11,943
  Min. kW 1.2 1.3
  Nom. kcal/h 2,150 3,010
  Max. kW 3.4 3.8
  Min. kcal/h 1,118 1,120
  Min. Btu/h 4,436 4,400
  Nom. kW 2.5 3.5
  Max. Btu/h 12,966 13,000
  Max. kcal/h 3,268 3,270
Pck (Crankcase heater mode) W 0.0 0.0
Nominal efficiency Annual energy consumption kWh 400.5 (0.000) 570 (0.000)
  Energy labeling Directive Heating B B
  Nominal efficiency-=-Cop 3.12 3.07
Heating Heating-=-Heating cdh degradation heating 0.25 0.25
Piping connections Liquid OD mm 6.35 6.35
  Gas OD mm 9.5 9.5
  Drain OD mm 18 18
  Heat insulation Both liquid and gas pipes Both liquid and gas pipes
Heating capacity Min. Btu/h 3,753 4,095
  Nom. Btu/h 10,919 12,966
  Max. kcal/h 4,730.0 5,159.0
  Max. Btu/h 18,767.0 20,473.0
  Nom. kW 3.2 3.8
  Min. kW 1.1 1.2
  Nom. kcal/h 2,752 3,267
  Min. kcal/h 946 1,032
  Max. kW 5.5, 3.14 (7) 6.0, 3.54 (7)
Pto (Thermostat off) W 31.0 31.0
Power input Cooling Min. kW 0.29 0.29
    Nom. kW 0.80 1.14
    Max. kW 1.30 1.30
  Heating Max. kW 2.14 2.89
    Min. kW 0.24 0.24
    Nom. kW 0.72 0.90
Indoor unit Yes Yes
Current Nominal running current (RLA) - 50Hz Heating A 3.6 (2), 3.5 (3), 3.4 (4) 4.0 (2), 3.8 (3), 3.7 (4)
    Cooling A 4.0 (2), 3.8 (3), 3.6 (4) 6.4 (2), 6.2 (3), 6.0 (4)
Notes For rated minimal heating capacity indoor unit fan set to SL tap For rated minimal heating capacity indoor unit fan set to SL tap
  220V 220V
  230V 230V
  240V 240V
  EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  Maximum heating capacity at -15°C outdoor temperature Maximum heating capacity at -15°C outdoor temperature