EHBX11CB3V / ERLQ011CAW1 EHBX11CB9W / ERLQ011CAW1 EHBX16CB9W / ERLQ014CAW1 EHBX16CB3V / ERLQ014CAW1 EHBX16CB3V / ERLQ016CAW1 EHBX16CB9W / ERLQ016CAW1
Space heating general Air to water unit Rated airflow (outdoor) m³/h 5,400 5,400 5,400 5,400 5,400 5,400
  Other Psb (Standby mode) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Poff (Off mode) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Pto (Thermostat off) kW 0.057 0.057 0.057 0.057 0.057 0.057
    Pck (Crankcase heater mode) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Capacity control 1.00 1.00 1.00 1.00 1.00 1.00
  Integrated supplementary heater Psup kW 3.00 9.00 9.00 3.00 3.00 9.00
    NOx emission mg/kWh 0.00 0.00 0.00 0.00 0.00 0.00
    Type of energy input Electrical Electrical Electrical Electrical Electrical Electrical
Water side Heat exchanger Water flow rate Cooling Nom. l/min 33.6 (5), 43.1 (6) 33.6 (5), 43.1 (6) 36.0 (5), 46.0 (6) 36.0 (5), 46.0 (6) 37.6 (5), 48.0 (6) 37.6 (5), 48.0 (6)
    Heating Nom. l/min 32.1 (7), 31.5 (8) 32.1 (7), 31.5 (8) 41.6 (7), 39.0 (8) 41.6 (7), 39.0 (8) 45.9 (7), 43.6 (8) 45.9 (7), 43.6 (8)
Pump Nominal ESP unit Heating kPa 37.0 (7), 39.0 (8) 37.0 (7), 39.0 (8) 49.0 (7), 57.0 (8) 49.0 (7), 57.0 (8) 33.0 (7), 42.0 (8) 33.0 (7), 42.0 (8)
    Cooling kPa 33.0 (5), 3.00 (6) 33.0 (5), 3.00 (6) 64.0 (5), 32.0 (6) 64.0 (5), 32.0 (6) 61.0 (5), 23.0 (6) 61.0 (5), 23.0 (6)
Space heating Cold climate water outlet 55°C General Prated at -22°C kW 6.99 6.99 8.15 8.15 9.12 9.12
      Annual energy consumption kWh 6,740 6,740 7,870 7,870 8,580 8,580
      Ƞs (Seasonal space heating efficiency) % 95.0 95.0 95.5 95.5 98.3 98.3
      Qhe Annual energy consumption (GCV) Gj 24.3 24.3 28.3 28.3 30.9 30.9
  Average climate water outlet 35°C A Condition (-7°CDB/-8°CWB) PERd % 105 105 105 105 93.2 93.2
      Pdh kW 8.88 8.88 10.7 10.7 12.4 12.4
      COPd 2.63 2.63 2.63 2.63 2.33 2.33
    C Condition (7°CDB/6°CWB) Pdh kW 5.74 5.74 5.05 5.05 5.74 5.74
      PERd % 271 271 228 228 271 271
      COPd 0.940 0.940 1.00 1.00 0.940 0.940
    D Condition (12°CDB/11°CWB) Pdh kW 6.50 6.50 5.16 5.16 6.50 6.50
      PERd % 359 359 268 268 359 359
      COPd 0.920 0.920 0.930 0.930 0.920 0.920
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 2.44 2.44 1.93 1.93 4.35 4.35
    General Annual energy consumption kWh 5,380 5,380 7,250 7,250 8,270 8,270
      Ƞs (Seasonal space heating efficiency) % 156 156 153 153 149 149
      Prated at -10°C kW 11.2 11.2 14.5 14.5 16.0 16.0
      Qhe Annual energy consumption (GCV) Gj 19.4 19.4 26.1 26.1 29.8 29.8
      Seasonal space heating eff. class 3.98 3.98 3.90 3.90 3.80 3.80
    B Condition (2°CDB/1°CWB) Pdh kW 6.03 6.03 7.71 7.71 8.62 8.62
      PERd % 162 162 163 163 150 150
      COPd 1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (bivalent temperature) Pdh kW 9.09 9.09 11.6 11.6 12.1 12.1
      PERd % 113 113 113 113 102 102
      Tbiv °C -5.00 -5.00 -5.00 -5.00 -4.00 -4.00
      COPd 2.82 2.82 2.83 2.83 2.56 2.56
    Tol (temperature operating limit) PERd % 93.6 93.6 104 104 82.0 82.0
      WTOL °C 35.0 35.0 35.0 35.0 35.0 35.0
      Pdh kW 8.76 8.76 12.6 12.6 11.7 11.7
      TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      COPd 2.34 2.34 2.60 2.60 2.05 2.05
  Warm climate water outlet 55°C General Prated at 2°C kW 7.58 7.58 9.84 9.84 10.3 10.3
      Ƞs (Seasonal space heating efficiency) % 125 125 135 135 136 136
      Annual energy consumption kWh 2,630 2,630 3,270 3,270 3,420 3,420
      Qhe Annual energy consumption (GCV) Gj 9.47 9.47 11.8 11.8 12.3 12.3
  Cold climate water outlet 35°C General Qhe Annual energy consumption (GCV) Gj 23.1 23.1 29.4 29.4 32.6 32.6
      Annual energy consumption kWh 6,430 6,430 8,170 8,170 9,050 9,050
      Ƞs (Seasonal space heating efficiency) % 148 148 141 141 137 137
      Prated at -22°C kW 10.3 10.3 12.3 12.3 13.3 13.3
  Warm climate water outlet 35°C General Prated at 2°C kW 9.06 9.06 10.9 10.9 11.4 11.4
      Ƞs (Seasonal space heating efficiency) % 192 192 199 199 199 199
      Qhe Annual energy consumption (GCV) Gj 7.02 7.02 8.46 8.46 8.92 8.92
      Annual energy consumption kWh 1,950 1,950 2,350 2,350 2,480 2,480
  Average climate water outlet 55°C A Condition (-7°CDB/-8°CWB) PERd % 79.6 79.6 70.4 70.4 71.2 71.2
      Pdh kW 8.83 8.83 9.97 9.97 12.2 12.2
      COPd 1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (bivalent temperature) Tbiv °C -7.00 -7.00 -6.00 -6.00 -7.00 -7.00
      Pdh kW 8.83 8.83 11.0 11.0 12.2 12.2
      PERd % 79.6 79.6 76.8 76.8 71.2 71.2
      COPd 1.99 1.99 1.92 1.92 1.78 1.78
    Tol (temperature operating limit) TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      Pdh kW 9.08 9.08 12.2 12.2 13.3 13.3
      PERd % 71.6 71.6 70.0 70.0 68.4 68.4
      WTOL °C 55.0 55.0 55.0 55.0 55.0 55.0
      COPd 1.79 1.79 1.75 1.75 1.71 1.71
    General Ƞs (Seasonal space heating efficiency) % 120 120 123 123 119 119
      Qhe Annual energy consumption (GCV) Gj 22.6 22.6 28.4 28.4 32.3 32.3
      Annual energy consumption kWh 6,260 6,260 7,900 7,900 8,970 8,970
      Prated at -10°C kW 9.99 9.99 12.7 12.7 13.9 13.9
      Seasonal space heating eff. class 3.09 3.09 3.16 3.16 3.06 3.06
    B Condition (2°CDB/1°CWB) Pdh kW 5.28 5.28 6.76 6.76 7.61 7.61
      PERd % 130 130 142 142 125 125
      COPd 1.00 1.00 1.00 1.00 1.00 1.00
    C Condition (7°CDB/6°CWB) Pdh kW 4.47 4.47 4.66 4.66 4.83 4.83
      PERd % 172 172 169 169 176 176
      COPd 0.950 0.950 0.950 0.950 1.00 1.00
    D Condition (12°CDB/11°CWB) PERd % 256 256 218 218 254 254
      Pdh kW 5.37 5.37 5.26 5.26 5.38 5.38
      COPd 0.930 0.930 0.940 0.940 0.930 0.930
    Rated heat output supplementary capacity Psup (at Tdesign -10°C) kW 0.910 0.910 0.550 0.550 0.580 0.580
Cooling capacity Nom. kW 12.1 (1), 11.7 (2) 12.1 (1), 11.7 (2) 12.7 (1), 12.6 (2) 12.7 (1), 12.6 (2) 13.8 (1), 13.1 (2) 13.8 (1), 13.1 (2)
Heating capacity Nom. kW 11.2 (1), 11.0 (2) 11.2 (1), 11.0 (2) 14.5 (1), 13.6 (2) 14.5 (1), 13.6 (2) 16.0 (1), 15.2 (2) 16.0 (1), 15.2 (2)
  Max. kW 8.60 (3), 8.60 (4) 8.60 (3), 8.60 (4) 10.6 (3), 10.8 (4) 10.6 (3), 10.8 (4) 11.4 (3), 10.9 (4) 11.4 (3), 10.9 (4)
General LW(A) Sound power level (according to EN14825) Indoor dB(A) 41.0 41.0 44.0 44.0 44.0 44.0
  Supplier/Manufacturer details Name and address Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Product description Low-temperature heat pump No No No No No No
LW(A) Sound power level (according to EN14825) Outdoor dB(A) 64.0 64.0 64.0 64.0 66.0 66.0
Power input Heating Max. kW 3.13 (3), 4.10 (4) 3.13 (3), 4.10 (4) 4.00 (3), 5.19 (4) 4.00 (3), 5.19 (4) 4.32 (3), 5.22 (4) 4.32 (3), 5.22 (4)
    Nom. kW 2.43 (1), 3.10 (2) 2.43 (1), 3.10 (2) 3.37 (1), 4.10 (2) 3.37 (1), 4.10 (2) 3.76 (1), 4.66 (2) 3.76 (1), 4.66 (2)
  Cooling Nom. kW 3.05 (1), 4.31 (2) 3.05 (1), 4.31 (2) 3.21 (1), 5.08 (2) 3.21 (1), 5.08 (2) 3.74 (1), 5.73 (2) 3.74 (1), 5.73 (2)
Sound condition Ecodesign and energy label 3.98 (1), 2.72 (2) 3.98 (1), 2.72 (2) 3.96 (1), 2.47 (2) 3.96 (1), 2.47 (2) 3.69 (1), 2.29 (2) 3.69 (1), 2.29 (2)
Notes Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C
  Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C
  Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C) Tamb 35°C - LWE 7°C (DT=5°C)
  Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C) Tamb 35°C - LWE 18°C (DT=5°C)
  DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C) DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)