FVXG25K2V1B / RXLG25M2V1B FVXG35K2V1B / RXLG35M2V1B
Poff (Off mode) W 1.0 1.0
Cooling Psb (Standby mode cooling) W 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25
Seasonal efficiency (according to EN14825) Cooling Pdesign kW 2.50 3.50
    Annual energy consumption kWh 131 186
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.99 6.59
    D Condition (20°C - 27/19) Pdc kW 2.32 2.36
      power input kW 0.21 0.22
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.18 10.54
    C Condition (25°C - 27/19) power input kW 0.22 0.24
      Pdc kW 2.21 2.27
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 10.07 9.45
    A Condition (35°C - 27/19) power input kW 0.71 1.02
      Pdc kW 2.50 3.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.52 3.43
    B Condition (30°C - 27/19) Pdc kW 1.94 2.58
      power input kW 0.24 0.44
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 8.08 5.80
  Heating (Average climate) Annual energy consumption kWh 988 1,187
    Pdesign kW 3.00 3.40
    Required back up heating cap at design conditions kW 0.00 0.00
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+ A+
    TBivalent Pdh (declared heating cap) kW 3.00 3.40
      Power input kW 1.28 1.61
      Tbiv (bivalent temperature) °C -10 -10
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.35 2.11
    C Condition (7°C) Pdh (declared heating cap) kW 1.45 1.54
      Power input kW 0.27 0.30
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.39 5.22
    TOL Tol (temperature operating limit) °C -25 -25
      Pdh (declared heating cap) kW 2.14 2.25
      Power input kW 0.89 0.96
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.41 2.35
    A Condition (-7°C) Pdh (declared heating cap) kW 2.60 2.97
      Power input kW 0.96 1.24
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.72 2.39
    D Condition (12°C) Pdh (declared heating cap) kW 1.71 1.82
      Power input kW 0.26 0.28
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.62 6.49
    B Condition (2°C) Power input kW 0.35 0.43
      Pdh (declared heating cap) kW 1.58 1.81
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.52 4.25
  Heating (Cold climate) Annual energy consumption kWh 2,611 3,175
    Pdesignh kW 4.30 4.90
    Required back up heating cap at design conditions kW 1.75 2.13
    Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-Seasonal efficiency according to en14825 heating cold climate energy efficiency class 3.54 3.31
    D Condition (12°C) Pdh (declared heating cap) kW 1.71 1.82
      Power input kW 0.26 0.28
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-D Condition (12°C)-=-Copd declared cop 6.62 6.49
    TBivalent Power input kW 1.79 2.00
      Tbiv (bivalent temperature) °C -15 -15
      Pdh (declared heating cap) kW 3.50 4.00
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-TBivalent-=-Copd declared cop 1.95 2.00
    TOL Tol (temperature operating limit) °C -25 -25
      Power input kW 0.89 0.96
      Pdh (declared heating cap) kW 2.14 2.25
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-TOL-=-Copd declared cop 2.41 2.35
    C Condition (7°C) Pdh (declared heating cap) kW 1.45 1.54
      Power input kW 0.27 0.30
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-C Condition (7°C)-=-Copd declared cop 5.39 5.22
    A Condition (-15°C) Pdh (declared heating cap) kW 3.50 4.00
      Power input kW 1.79 2.00
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-A Condition (-15°C)-=-Copd declared cop 1.95 2.00
    A Condition (-7°C) Pdh (declared heating cap) kW 2.60 2.97
      Power input kW 0.96 1.24
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-A Condition (-7°C)-=-Copd declared cop 2.72 2.39
    B Condition (2°C) Pdh (declared heating cap) kW 1.58 1.81
      Power input kW 0.35 0.43
      Seasonal efficiency (according to EN14825)-=-Heating (Cold climate)-=-B Condition (2°C)-=-Copd declared cop 4.52 4.25
Cooling capacity Nom. Btu/h 8,530 (2) 11,940 (2)
  Min. kW 1.2 1.4
  Nom. kcal/h 2,150 (2) 3,010 (2)
  Max. kW 5.1 5.6
  Min. kcal/h 1,030 1,200
  Min. Btu/h 4,100 4,780
  Nom. kW 2.5 (2) 3.5 (2)
  Max. Btu/h 17,400 19,100
  Max. kcal/h 4,380 4,810
Pck (Crankcase heater mode) W 0.0 0.0
Nominal efficiency Annual energy consumption kWh 355 (0.000) 510 (0.000)
  Energy labeling Directive Heating A A
  Nominal efficiency-=-Cop 3.52 (1) 3.43 (1)
Heating Psb (Standby mode heating) W 1.0 1.0
  Heating-=-Heating cdh degradation heating 0.25 0.25
Piping connections Liquid OD mm 6.35 6.35
  Gas OD mm 9.5 9.5
  Drain OD mm 18 18
  Heat insulation Both liquid and gas pipes Both liquid and gas pipes
Heating capacity Min. Btu/h 3,400 (6) 3,750 (6)
  Nom. Btu/h 15,350 (2) 19,100 (2)
  Max. kcal/h 5,590 6,020
  Max. Btu/h 22,180 23,880
  Nom. kW 4.5 (2) 5.6 (2)
  Min. kW 1.0 (6) 1.1 (6)
  Nom. kcal/h 3,870 (2) 4,810 (2)
  Min. kcal/h 860 (6) 950 (6)
  Max. kW 6.5, 3.5 (7) 7.0, 4.0 (7)
Pto (Thermostat off) W 60.0 60.0
Power input Cooling Min. kW 0.250 0.250
    Nom. kW 0.710 (2) 1.020 (2)
    Max. kW 1.850 2.040
  Heating Max. kW 1.840 2.350
    Min. kW 0.250 0.250
    Nom. kW 1.160 (2) 1.550 (2)
Indoor unit Yes Yes
Current Nominal running current (RLA) - 50Hz Heating A 6.1 (3), 5.8 (4), 5.5 (5) 7.7 (3), 7.3 (4), 7.0 (5)
    Cooling A 3.8 (3), 3.7 (4), 3.6 (5) 5.2 (3), 4.9 (4), 4.7 (5)
Notes EER/COP according to Eurovent 2012, for use outside EU only EER/COP according to Eurovent 2012, for use outside EU only
  Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  220V 220V
  230V 230V
  240V 240V
  For rated minimal heating capacity indoor unit fan set to SL tap For rated minimal heating capacity indoor unit fan set to SL tap
  Maximum heating capacity at -15°C outdoor temperature Maximum heating capacity at -15°C outdoor temperature