Specifications Table for FVXM-F / RXM-M9

FVXM25FV1B9 / RXM25M3V1B9 FVXM25FV1B / RXM25M3V1B9 FVXM35FV1B9 / RXM35M3V1B9 FVXM35FV1B / RXM35M3V1B9 FVXM50FV1B9 / RXM50M3V1B9 FVXM50FV1B / RXM50M3V1B9
Cooling capacity Min. kW 1.30 1.30 1.40 1.40 1.40 1.40
  Nom. kW 2.50 2.50 3.50 3.50 5.00 5.00
  Max. kW 3.00 3.00 3.80 3.80 5.60 5.60
Heating capacity Min. kW 1.30 1.30 1.40 1.40 1.40 1.40
  Nom. kW 3.40 3.40 4.50 4.50 5.80 5.80
  Max. kW 4.50 4.50 5.00 5.00 8.10 8.10
Nominal efficiency EER   4.20 4.20 3.21 3.21 3.23 3.23
  COP   4.42 4.42 3.78 3.78 3.63 3.63
  Annual energy consumption kWh 298 298 545 545 773 773
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Space cooling Capacity Pdesign kW 2.50 2.50 3.50 3.50 5.00 5.00
  Energy efficiency class   A++ A++ A++ A++ A++ A++
  SEER   7.20 7.20 6.43 6.43 6.80 6.80
  Annual energy consumption kWh/a 120 120 190 190 257 257
Space heating (Average climate) Capacity Pdesign kW 2.40 2.40 2.90 2.90 4.20 4.20
  Energy efficiency class   A+ A+ A+ A+ A+ A+
  SCOP/A   4.56 4.56 4.00 4.00 4.00 4.00
  Pdh Heating capacity at -10° kW 2.23 2.23 2.40 2.40 2.23 2.23
  Annual energy consumption kWh/a 737 737 1,015 1,015 1,471 1,471
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data
  (2) - See separate drawing for operation range (2) - See separate drawing for operation range (2) - See separate drawing for operation range (2) - See separate drawing for operation range (2) - See separate drawing for operation range (2) - See separate drawing for operation range
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.