Specifications Table for FCQG-F / RZQSG-LV1/LY1

FCQG71FVEB / RZQSG71L2V1B FCQG100FVEB / RZQSG100L7Y1B FCQG100FVEB / RZQSG100L7V1B FCQG100FVEB / RZQSG100L7Y1B9 FCQG125FVEB / RZQSG125L7Y1B FCQG125FVEB / RZQSG125L7V1B FCQG125FVEB / RZQSG125L7Y1B9
Cooling capacity Nom. kW 6.8 9.5 (3) 9.5 9.5 12.0 (3) 12.0 12.0
Heating capacity Nom. kW 7.5 10.8 (4) 10.8 10.8 13.5 (4) 13.5 13.5
Nominal efficiency EER   3.21 3.30 3.30 3.30 3.21 3.21 3.21
  COP   3.61 3.54 3.54 3.54 3.41 3.41 3.41
  Annual energy consumption kWh 971 1,440 1,440 1,440 1,870 1,870 1,870
  Energy labeling Directive Cooling   A A A A A A A
    Heating   A A B B B B B
Space cooling Energy efficiency class   A   A A   A A
  Capacity Pdesign kW 6.80   9.50 9.50   12.00 12.00
  SEER   5.11 5.11 (6) 5.11 5.11 5.11 (6) 5.11 5.11
  Annual energy consumption kWh/a 466   650.685 650.685   821.918 821.918
Space heating (Average climate) Energy efficiency class   A   A A   A A
  Capacity Pdesign kW 6.33   7.60 7.60   8.03 8.03
  SCOP/A   3.81 3.80 (6) 3.80 3.80 3.81 (6) 3.81 3.81
  Annual energy consumption kWh/a 2,327   2,799 2,799   2,949 2,949
Notes (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Energy label: scale from A (most efficient) to G (less efficient) (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Energy label: scale from A (most efficient) to G (less efficient) (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
    (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m     (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m    
    (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m     (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m    
    (5) - Annual energy consumption is according to Energy labeling directive 2002/31/EC     (5) - Annual energy consumption is according to Energy labeling directive 2002/31/EC    
    (6) - SEER and SCOP are according to EN 14825     (6) - SEER and SCOP are according to EN 14825    
    (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load     (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load