Specifications Table for ATXM-R / ARXM-A

ATXM25R2V1B / ARXM25A5V1B ATXM25R5V1B / ARXM25A5V1B ATXM35R2V1B / ARXM35A5V1B ATXM35R5V1B / ARXM35A5V1B
Cooling capacity Min. kW 0.9 0.9 0.9 0.9
  Nom. kW 2.5 2.5 3.5 3.5
  Max. kW 3.8 3.8 4.4 4.4
Heating capacity Min. kW 0.8 0.8 0.8 0.8
  Nom. kW 2.8 2.8 4 4
  Max. kW 5 5 5.5 5.5
Nominal efficiency EER   5.1 5.1 4.5 4.5
  COP   5 5 4.45 4.45
  Annual energy consumption kWh 245 245 389 389
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Space cooling Energy efficiency class   A+++ A+++ A+++ A+++
  Capacity Pdesign kW 2.5 2.5 3.5 3.5
  SEER   9.3 9.3 9.1 9.1
  Annual energy consumption kWh/a 94 94 135 135
Space heating (Average climate) Energy efficiency class   A+++ A+++ A+++ A+++
  Capacity Pdesign kW 2.4 2.4 2.5 2.5
  SCOP/A   5.15 5.15 5.15 5.15
  Pdh Heating capacity at -10° kW 2.4 2.4 2.5 2.5
  Annual energy consumption kWh/a 652 652 679 679
Notes (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data