AZQS71B2V1B |
AZQS100B8V1B |
AZQS125B8V1B |
AZQS140B8V1B |
Dimensions
|
Unit
|
Height
|
mm
|
770
|
990
|
990
|
1,430
|
|
|
Width
|
mm
|
900
|
940
|
940
|
940
|
|
|
Depth
|
mm
|
320
|
320
|
320
|
320
|
Weight
|
Unit
|
kg
|
67
|
72.8
|
74.3
|
94.9
|
Compressor
|
Type
|
|
Hermetically sealed swing compressor
|
Hermetically sealed swing compressor
|
Hermetically sealed swing compressor
|
Hermetically sealed swing compressor
|
Operation range
|
Cooling
|
Ambient
|
Min.
|
°CDB
|
-5
|
-5.0
|
-5.0
|
-5.0
|
|
|
|
Max.
|
°CDB
|
46
|
46.0
|
46.0
|
46.0
|
|
Heating
|
Ambient
|
Min.
|
°CWB
|
-15
|
-15.0
|
-15.0
|
-15.0
|
|
|
|
Max.
|
°CWB
|
15.5
|
15.5
|
15.5
|
15.5
|
Sound power level
|
Cooling
|
dBA
|
64
|
70.0
|
71.0
|
70.0
|
|
Heating
|
dBA
|
|
70.0
|
71.0
|
70.0
|
Sound pressure level
|
Cooling
|
Nom.
|
dBA
|
48
|
53
|
54
|
53
|
|
Heating
|
Nom.
|
dBA
|
50
|
57
|
58
|
54
|
|
Night quiet mode
|
Level 1
|
dBA
|
43
|
49
|
49
|
49
|
Refrigerant
|
Type
|
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
|
Charge
|
kg
|
2.75
|
2.9
|
2.9
|
4.0
|
|
GWP
|
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
Piping connections
|
Liquid
|
OD
|
mm
|
9.52
|
9.52
|
9.52
|
9.52
|
|
Gas
|
OD
|
mm
|
15.9
|
15.9
|
15.9
|
15.9
|
|
Piping length
|
OU - IU
|
Max.
|
m
|
50
|
50, 30 (1)
|
50, 30 (1)
|
50, 30 (1)
|
|
|
System
|
Equivalent
|
m
|
70
|
70, 40 (1)
|
70, 40 (1)
|
70, 40 (1)
|
|
|
|
Chargeless
|
m
|
30
|
30
|
30
|
30
|
|
Additional refrigerant charge
|
kg/m
|
See installation manual
|
See installation manual
|
See installation manual
|
See installation manual
|
|
Level difference
|
IU - OU
|
Max.
|
m
|
30.0
|
30.0
|
30.0
|
30.0
|
|
|
IU - IU
|
Max.
|
m
|
|
0.5
|
0.5
|
0.5
|
Standard Accessories
|
Tie-wraps
|
2
|
|
Installation manual
|
1
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
|
Frequency
|
Hz
|
50
|
50
|
50
|
50
|
|
Voltage
|
V
|
220-240
|
220-240
|
220-240
|
220-240
|
Current - 50Hz
|
Maximum fuse amps (MFA)
|
A
|
|
32
|
32
|
40
|
Notes
|
(1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
(1) - For combination with FCAG~AVEB indoor units
|
(1) - For combination with FCAG~AVEB indoor units
|
(1) - For combination with FCAG~AVEB indoor units
|
|
(2) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A
|
(2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
|
(2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
|
(2) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
|
|
(3) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
|
(3) - Ssc: Short-circuit power
|
(3) - Ssc: Short-circuit power
|
(3) - Ssc: Short-circuit power
|
|
(4) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
|
(4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
(4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
(4) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
|
(5) - Contains fluorinated greenhouse gases
|
(5) - See separate drawing for electrical data
|
(5) - See separate drawing for electrical data
|
(5) - See separate drawing for electrical data
|
|
|
(6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A
|
(6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A
|
(6) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A
|