| ERQ100A7V1B | ERQ125A7V1B | ERQ140A7V1B | |||||
|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 53 | 55 | ||
| Cooling | Nom. | dBA | 51 | 53 | |||
| Standard Accessories | Installation manual | 1 | 1 | 1 | |||
| Operation manual | 1 | 1 | 1 | ||||
| Refrigerant | Charge | TCO2Eq | 8.4 | 8.4 | |||
| GWP | 2,087.5 | 2,087.5 | |||||
| Charge | kg | 4.0 | 4.0 | ||||
| Type | R-410A | R-410A | |||||
| Operation range | Cooling | Max. | °CDB | 46 | 46 | ||
| Min. | °CDB | -5 | -5 | ||||
| Heating | Max. | °CWB | 15.5 | 15.5 | |||
| Min. | °CWB | -20 | -20 | ||||
| Cooling capacity | Nom. | kW | 14.0 (1) | 15.5 (1) | |||
| Piping connections | Liquid | OD | mm | 9.52 | 9.52 | ||
| Type | Flare connection | Flare connection | |||||
| Gas | OD | mm | 15.9 | 19.1 | |||
| Type | Flare connection | Braze connection | |||||
| Drain | OD | mm | 26x3 | 26x3 | |||
| Quantity | 3 | 3 | |||||
| Power input | Cooling | Nom. | kW | 3.51 (1) | 4.53 (1) | ||
| Sound power level | Cooling | Nom. | dBA | 67 | 69 | ||
| COP | 4.56 (2) | 4.15 (2) | 3.94 (2) | ||||
| Dimensions | Unit | Width | mm | 900 | 900 | ||
| Depth | mm | 320 | 320 | ||||
| Height | mm | 1,345 | 1,345 | ||||
| Weight | Unit | kg | 120 | 120 | |||
| Fan | Air flow rate | Heating | Nom. | m³/min | 105 | 105 | |
| Cooling | Nom. | m³/min | 106 | 106 | |||
| EER | 3.99 (1) | 3.99 (1) | 3.42 (1) | ||||
| Heating capacity | Nom. | kW | 16.0 (2) | 18.0 (2) | |||
| Power supply | Phase | 1N~ | 1N~ | ||||
| Name | V1 | V1 | |||||
| Frequency | Hz | 50 | 50 | ||||
| Voltage | V | 220-240 | 220-240 | ||||
| Notes | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m | (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m | ||||
| (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m | |||||
| (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | ||||||
| (4) - Sound values are measured in a semi-anechoic room. | (4) - Sound values are measured in a semi-anechoic room. | ||||||
| (5) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB | (5) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB | ||||||
| (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | ||||||
| (7) - Maximum allowable voltage range variation between phases is 2%. | (7) - Maximum allowable voltage range variation between phases is 2%. | ||||||
| (8) - Select wire size based on the value of MCA | (8) - Select wire size based on the value of MCA | ||||||
| (9) - Use a circuit breaker instead of a fuse. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). | (9) - Use a circuit breaker instead of a fuse. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). | ||||||
| (10) - MSC means the maximum current during start up of the compressor | (10) - MSC means the maximum current during start up of the compressor | ||||||
| (11) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (11) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | ||||||
| (12) - Ssc: Short-circuit power | (12) - Ssc: Short-circuit power | ||||||
| (13) - Contains fluorinated greenhouse gases | (13) - Contains fluorinated greenhouse gases | ||||||
| Cooling capacity | Nom. | kW | 11.2 (1) | ||||
| Heating capacity | Nom. | kW | 12.5 (2) | ||||
| Power input | Cooling | Nom. | kW | 2.81 (1) | |||
| Heating | Nom. | kW | 2.74 (2) | ||||
| Dimensions | Unit | Height | mm | 1345 | |||
| Width | mm | 900 | |||||
| Depth | mm | 320 | |||||
| Weight | Unit | kg | 120 | ||||
| Fan | Air flow rate | Cooling | Nom. | m³/min | 106 | ||
| Heating | Nom. | m³/min | 102 | ||||
| Operation range | Cooling | Min. | °CDB | -5 | |||
| Max. | °CDB | 46 | |||||
| Heating | Min. | °CWB | -20 | ||||
| Max. | °CWB | 15.5 | |||||
| Sound power level | Cooling | Nom. | dBA | 66 | |||
| Sound pressure level | Cooling | Nom. | dBA | 50 | |||
| Heating | Nom. | dBA | 52 | ||||
| Refrigerant | Type | R-410A | |||||
| Charge | kg | 4 | |||||
| Charge | tCO2Eq | 8.4 | |||||
| GWP | 2087.5 | ||||||
| Piping connections | Liquid | Type | Flare connection | ||||
| OD | mm | 9.52 | |||||
| Gas | Type | Flare connection | |||||
| OD | mm | 15.9 | |||||
| Drain | Quantity | 3 | |||||
| OD | mm | 26x3 | |||||
| Power supply | Name | V1 | |||||
| Phase | 1N~ | ||||||
| Power supply-=-Frequency | Frequency | 50 | |||||
| Power supply-=-Voltage | Voltage | 220-240 | |||||
| Standard Accessories | Connection pipes | 3 | |||||