Specifications Table for FDXM-F9 / 2MXM-N

FDXM25F3V1B9 / FDXM25F3V1B9 / 2MXM40N2V1B FDXM25F3V1B9 / FDXM35F3V1B9 / 2MXM40N2V1B FDXM25F3V1B9 / FDXM25F3V1B9 / 2MXM50N2V1B FDXM25F3V1B9 / FDXM35F3V1B9 / 2MXM50N2V1B FDXM25F3V1B9 / FDXM50F3V1B9 / 2MXM50N2V1B FDXM35F3V1B9 / FDXM35F3V1B9 / 2MXM50N2V1B FDXM35F3V1B9 / FDXM50F3V1B9 / 2MXM50N2V1B
Cooling capacity Nom. kW 4.00 4.00 5.00 5.00 5.00 5.00 5.00
Space cooling SEER   6.28 6.16 6.21 6.24 6.51 6.41 6.40
  Annual energy consumption kWh/a 223 228 282 281 269 273 274
  Capacity Pdesign kW 4.00 4.00 5.00 5.00 5.00 5.00 5.00
  Energy efficiency class   A++ A++ A++ A++ A++ A++ A++
Space heating (Average climate) Capacity Pdesign kW 3.20 3.20 4.20 4.20 4.20 4.20 4.20
  SCOP/A   4.01 4.05 3.78 3.79 3.86 3.82 3.89
  Energy efficiency class   A+ A+ A A A A A
  Pdh Heating capacity at -10° kW 2.61 2.62 3.42 3.43 3.55 3.44 3.57
  Annual energy consumption kWh/a 1,117 1,106 1,555 1,550 1,523 1,538 1,509
Nominal efficiency Annual energy consumption kWh 563 556 779 769 712 760 704
  EER   3.55 3.60 3.21 3.25 3.51 3.29 3.55
  COP   4.13 4.17 3.66 3.64 3.61 3.62 3.61
  Energy labeling Directive Cooling   A A A A A A A
    Heating   A A A A A A A
Heating capacity Nom. kW 4.20 4.20 5.60 5.60 5.60 5.60 5.60
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data