FDXM50F3V1B9 / RXM50A5V1B |
FDXM60F3V1B9 / RXM60A5V1B |
Cooling capacity
|
Min.
|
kW
|
1.70
|
1.7
|
|
Nom.
|
kW
|
5.00
|
6
|
|
Max.
|
kW
|
5.30
|
6.5
|
Heating capacity
|
Min.
|
kW
|
1.70
|
1.7
|
|
Nom.
|
kW
|
5.80
|
7
|
|
Max.
|
kW
|
6.00
|
7.1
|
Nominal efficiency
|
EER
|
|
3.06
|
2.93
|
|
COP
|
|
3.10
|
3.21
|
|
Annual energy consumption
|
kWh
|
817
|
1024
|
|
Energy labeling Directive
|
Cooling
|
|
B
|
C
|
|
|
Heating
|
|
D
|
C
|
Space cooling
|
Energy efficiency class
|
|
A+
|
A
|
|
Capacity
|
Pdesign
|
kW
|
5.00
|
6
|
|
SEER
|
|
5.77
|
5.56
|
|
Annual energy consumption
|
kWh/a
|
303
|
378
|
Space heating (Average climate)
|
Energy efficiency class
|
|
A
|
A
|
|
Capacity
|
Pdesign
|
kW
|
4.00
|
4.6
|
|
SCOP/A
|
|
3.93
|
3.8
|
|
Pdh Heating capacity at -10°
|
kW
|
3.54
|
3.94
|
|
Annual energy consumption
|
kWh/a
|
1424
|
1693
|
Notes
|
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
|
(3) - See separate drawing for operation range
|
|
|
(4) - See separate drawing for electrical data
|