Specifications Table for FDXM-F9 / RXM-N

FDXM50F3V1B9 / RXM50N2V1B
Cooling capacity Min. kW 1.70
  Max. kW 5.30
  Nom. kW 5.00
Nominal efficiency EER   3.06
  Annual energy consumption kWh 817
  COP   3.10
  Energy labeling Directive Cooling   B
    Heating   D
Heating capacity Nom. kW 5.80
  Min. kW 1.70
  Max. kW 6.00
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data