| FDXM50F3V1B9 / RXM50N2V1B | ||||
|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.70 | |
| Max. | kW | 5.30 | ||
| Nom. | kW | 5.00 | ||
| Nominal efficiency | EER | 3.06 | ||
| Annual energy consumption | kWh | 817 | ||
| COP | 3.10 | |||
| Energy labeling Directive | Cooling | B | ||
| Heating | D | |||
| Heating capacity | Nom. | kW | 5.80 | |
| Min. | kW | 1.70 | ||
| Max. | kW | 6.00 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | ||||