FFA35A2VEB9 / FFA35A2VEB9 / FFA35A2VEB9 / RZQSG100L8Y1B |
FFA50A2VEB9 / FFA50A2VEB9 / RZQSG100L8Y1B |
FFA35A2VEB9 / FFA35A2VEB9 / FFA35A2VEB9 / FFA35A2VEB9 / RZQSG125L8Y1B |
FFA50A2VEB9 / FFA50A2VEB9 / FFA50A2VEB9 / RZQSG125L8Y1B |
FFA60A2VEB9 / FFA60A2VEB9 / RZQSG125L8Y1B |
Cooling capacity
|
Nom.
|
kW
|
9.5
|
9.5
|
12.0
|
12.0
|
12.0
|
Space cooling
|
SEER
|
|
5.10
|
5.10
|
4.80
|
4.80
|
5.10
|
|
Annual energy consumption
|
kWh/a
|
652
|
652
|
875
|
875
|
824
|
|
Capacity
|
Pdesign
|
kW
|
9.50
|
9.50
|
12.00
|
12.00
|
12.00
|
|
Energy efficiency class
|
|
A
|
A
|
B
|
B
|
A
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
7.60
|
7.60
|
7.60
|
7.60
|
12.71
|
|
SCOP/A
|
|
3.80
|
3.80
|
3.80
|
3.80
|
3.80
|
|
Energy efficiency class
|
|
A
|
A
|
A
|
A
|
A
|
|
Annual energy consumption
|
kWh/a
|
2,800
|
2,800
|
2,800
|
2,800
|
4,683
|
Nominal efficiency
|
EER
|
|
3.30
|
3.03
|
3.01
|
2.90
|
3.61
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|