Specifications Table for FHA-A / RZQSG-L3/9V1

FHA35AVEB / FHA35AVEB / RZQSG71L3V1B FHA71AVEB / RZQSG71L3V1B FHA35AVEB / FHA35AVEB / FHA35AVEB / RZQSG100L9V1B FHA50AVEB / FHA50AVEB / RZQSG100L9V1B FHA35AVEB / FHA35AVEB / FHA35AVEB / FHA35AVEB / RZQSG125L9V1B FHA50AVEB / FHA50AVEB / FHA50AVEB / RZQSG125L9V1B FHA60AVEB / FHA60AVEB / RZQSG125L9V1B
Cooling capacity Nom. kW   6.80 (1)
Space cooling Annual energy consumption kWh/a 467 425 652 652 875 875 875
  Capacity Pdesign kW 6.80 6.80 9.50 9.50 12.0 12.0 12.0
Space heating (Average climate) Capacity Pdesign kW 6.00 7.60 7.60 7.60 7.60 7.60 7.60
  Annual energy consumption kWh/a 2,211 2,727 2,800 2,800 2,800 2,800 2,800
Nominal efficiency EER     3.46 (3)
  Annual energy consumption kWh   983
  COP     4.00 (3)
  Energy labeling Directive Cooling     A
    Heating     A
Heating capacity Nom. kW   7.50 (2)
Space cooling SEER   5.10 5.61 5.10 5.10 4.80 4.80 4.80
  Energy efficiency class   A A+ A A B B B
Space heating (Average climate) SCOP/A   3.80 3.90 3.80 3.80 3.80 3.80 3.80
  Energy efficiency class   A A A A A A A
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only