Specifications Table for FNA-A / RZQSG-L(8)Y1

FNA35A2VEB / FNA35A2VEB / FNA35A2VEB / RZQSG100L8Y1B FNA50A2VEB / FNA50A2VEB / RZQSG100L8Y1B FNA35A2VEB / FNA35A2VEB / FNA35A2VEB / FNA35A2VEB / RZQSG125L8Y1B FNA50A2VEB / FNA50A2VEB / FNA50A2VEB / RZQSG125L8Y1B FNA60A2VEB / FNA60A2VEB / RZQSG125L8Y1B
Cooling capacity Nom. kW 9.50 (1) 9.50 (1) 12.0 (1) 12.0 (1) 12.0 (1)
Space cooling Annual energy consumption kWh/a 693 652 875 875 875
  Capacity Pdesign kW 9.50 9.50 12.0 12.0 12.0
Space heating (Average climate) Capacity Pdesign kW 7.10 7.60 7.60 7.60 7.60
  Annual energy consumption kWh/a 2,616 2,800 2,800 2,800 2,800
Nominal efficiency EER   2.56 (3) 3.02 (3) 2.57 (3) 2.95 (3) 2.46 (3)
  COP   2.66 (3) 3.26 (3) 2.90 (3) 3.44 (3) 3.08 (3)
  Energy labeling Directive Cooling   E B E C E
    Heating   D C D B D
Heating capacity Nom. kW 10.8 (2) 10.8 (2) 13.5 (2) 13.5 (2) 13.5 (2)
Space cooling SEER   4.80 5.10 4.80 4.80 4.80
  Energy efficiency class   B A B B B
Space heating (Average climate) SCOP/A   3.80 3.80 3.80 3.80 3.80
  Energy efficiency class   A A A A A
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only (3) - EER/COP according to Eurovent 2012, for use outside EU only