Specifications Table for FTXJ-AW9 / RXJ-A

FTXJ20A2V1BW9 / RXJ20A5V1B FTXJ25A2V1BW9 / RXJ25A5V1B FTXJ35A2V1BW9 / RXJ35A5V1B FTXJ42A2V1BW9 / RXJ42A2V1B FTXJ50A2V1BW9 / RXJ50A2V1B
Cooling capacity Min. kW 1.3 1.3 1.4 1.7 1.7
  Nom. kW 2 2.5 3.4 4.2 5
  Max. kW 2.6 3.2 4 5 5.3
Heating capacity Min. kW 1.3 1.3 1.4 1.7 1.7
  Nom. kW 2.5 2.8 4 5.4 5.8
  Max. kW 3.5 4.7 5.2 6 6.5
Nominal efficiency EER   4.7 4.46 4.37 3.99 3.68
  COP   5 5 4.04 4.12 4
  Annual energy consumption kWh 213 280 389 526 679
  Energy labeling Directive Cooling   A A A A A
    Heating   A A A A A
Space cooling Energy efficiency class   A+++ A+++ A+++ A++ A++
  Capacity Pdesign kW 2 2.5 3.4 4.2 5
  SEER   8.75 8.74 8.73 7.5 7.33
  Annual energy consumption kWh/a 80 100 136 196 239
Space heating (Average climate) Energy efficiency class   A+++ A+++ A+++ A++ A++
  Capacity Pdesign kW 2.4 2.45 2.5 3.8 4
  SCOP/A   5.15 5.15 5.15 4.6 4.6
  Pdh Heating capacity at -10° kW 2.02 2.07 2.11 3.26 3.44
  Annual energy consumption kWh/a 652 666 680 1,156 1,218
Notes (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data