FTXM25R5V1B / FTXM25R5V1B / 2MXM50A2V1B8 |
FTXM25R2V1B / FTXM25R2V1B / 2MXM50A2V1B8 |
FTXM35R5V1B / FTXM35R5V1B / 2MXM68A2V1B8 |
FTXM35R2V1B / FTXM35R2V1B / 2MXM68A2V1B8 |
Cooling capacity
|
Nom.
|
kW
|
5.00
|
5.00
|
6.8
|
6.8
|
Heating capacity
|
Nom.
|
kW
|
5.60
|
5.60
|
8.60
|
8.60
|
Nominal efficiency
|
EER
|
|
4.01
|
4.01
|
3.94
|
3.94
|
|
COP
|
|
4.08
|
4.08
|
3.81
|
3.81
|
|
Annual energy consumption
|
kWh
|
623
|
623
|
863
|
863
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
A
|
|
|
Heating
|
|
A
|
A
|
Space cooling
|
Energy efficiency class
|
|
A+++
|
A+++
|
A++
|
A++
|
|
Capacity
|
Pdesign
|
kW
|
5.00
|
5.00
|
6.80
|
6.80
|
|
SEER
|
|
8.53
|
8.53
|
6.97
|
6.97
|
|
Annual energy consumption
|
kWh/a
|
205
|
205
|
342
|
342
|
Space heating (Average climate)
|
Energy efficiency class
|
|
A++
|
A++
|
A+
|
A+
|
|
Capacity
|
Pdesign
|
kW
|
4.20
|
4.20
|
4.80
|
4.80
|
|
SCOP/A
|
|
4.61
|
4.61
|
4.00
|
4.00
|
|
Pdh Heating capacity at -10°
|
kW
|
3.20
|
3.20
|
3.73
|
3.73
|
|
Annual energy consumption
|
kWh/a
|
1,275
|
1,275
|
1,680
|
1,680
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|