FXAA15AUV1B |
FXAA20AUV1B |
FXAA25AUV1B |
FXAA32AUV1B |
FXAA40AUV1B |
FXAA50AUV1B |
FXAA63AUV1B |
Sound pressure level
|
Heating
|
At high fan speed
|
dBA
|
33.0
|
34.0
|
36.0
|
38.5
|
38.0
|
42.0
|
47.0
|
|
|
At low fan speed
|
dBA
|
28.5
|
28.5
|
28.5
|
28.5
|
33.5
|
35.5
|
38.5
|
|
|
At medium fan speed
|
dBA
|
31.0
|
31.5
|
32.5
|
33.5
|
36.0
|
39.0
|
43.0
|
|
Cooling
|
At low fan speed
|
dBA
|
28.5
|
28.5
|
28.5
|
28.5
|
33.5
|
35.5
|
38.5
|
|
|
At high fan speed
|
dBA
|
32.0
|
33.0
|
35.0
|
37.5
|
37.0
|
41.0
|
46.5
|
|
|
At medium fan speed
|
dBA
|
30.5
|
31.0
|
32.0
|
33.0
|
35.5
|
38.5
|
42.5
|
Standard Accessories
|
Installation and operation manual
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Installation plate
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Installation pattern
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Screw bag
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
Wire clamp material
|
4
|
4
|
4
|
4
|
4
|
4
|
4
|
|
Heat insulating tape
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
General safety precautions
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
Refrigerant
|
GWP
|
|
675.0
|
675.0
|
675.0
|
675.0
|
675.0
|
675.0
|
675.0
|
|
Type
|
|
R-32
|
R-32
|
R-32
|
R-32
|
R-32
|
R-32
|
R-32
|
Power input - 50Hz
|
Cooling
|
At high fan speed
|
kW
|
0.017
|
0.019
|
0.028
|
0.030
|
0.025
|
0.033
|
0.050
|
|
Heating
|
At high fan speed
|
kW
|
0.025
|
0.029
|
0.034
|
0.035
|
0.030
|
0.039
|
0.060
|
Cooling capacity
|
Total capacity
|
At high fan speed
|
kW
|
1.7
|
2.2
|
2.8
|
3.6
|
4.5
|
5.6
|
7.1
|
Piping connections
|
Liquid
|
OD
|
mm
|
6
|
6
|
6
|
6
|
6
|
6
|
6
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Gas
|
OD
|
mm
|
9.52
|
9.52
|
9.52
|
9.52
|
12.70
|
12.70
|
12.70
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Drain
|
|
VP13 (I.D. 15/O.D. 18)
|
VP13 (I.D. 15/O.D. 18)
|
VP13 (I.D. 15/O.D. 18)
|
VP13 (I.D. 15/O.D. 18)
|
VP13 (I.D. 15/O.D. 18)
|
VP13 (I.D. 15/O.D. 18)
|
VP13 (I.D. 15/O.D. 18)
|
Sound power level
|
Cooling
|
At high fan speed
|
dBA
|
51.0
|
52.0
|
53.0
|
55.0
|
55.0
|
58.0
|
63.0
|
Air filter
|
Type
|
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Removable / washable
|
Dimensions
|
Unit
|
Width
|
mm
|
795
|
795
|
795
|
795
|
1,050
|
1,050
|
1,050
|
|
|
Depth
|
mm
|
266
|
266
|
266
|
266
|
269
|
269
|
269
|
|
|
Height
|
mm
|
290
|
290
|
290
|
290
|
290
|
290
|
290
|
Casing
|
Colour
|
|
White
|
White
|
White
|
White
|
White
|
White
|
White
|
Weight
|
Unit
|
kg
|
12
|
12
|
12
|
12
|
15
|
15
|
15
|
Fan
|
Air flow rate - 50Hz
|
Cooling
|
At high fan speed
|
m³/min
|
7.1
|
7.9
|
8.3
|
9.4
|
12.2
|
14.2
|
18.2
|
|
|
|
At low fan speed
|
m³/min
|
6.5
|
6.5
|
6.5
|
6.5
|
9.8
|
10.9
|
12.9
|
Heating capacity
|
Total capacity
|
At high fan speed
|
kW
|
1.9
|
2.5
|
3.2
|
4.0
|
5.0
|
6.3
|
8.0
|
Current - 50Hz
|
Maximum fuse amps (MFA)
|
A
|
6
|
6
|
6
|
6
|
6
|
6
|
6
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
|
Name
|
|
V1
|
V1
|
V1
|
V1
|
V1
|
V1
|
V1
|
|
Frequency
|
Hz
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
|
Voltage
|
V
|
220-240
|
220-240
|
220-240
|
220-240
|
220-240
|
220-240
|
220-240
|
Notes
|
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
|
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
|
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
|
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
|
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
|
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
|
(1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
|
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(3) - The sound power level is an absolute value indicating the power which a sound source generates.
|
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
|
(6) - MCA/MFA: MCA = 1.1 x FLA
|
(6) - MCA/MFA: MCA = 1.1 x FLA
|
(6) - MCA/MFA: MCA = 1.1 x FLA
|
(6) - MCA/MFA: MCA = 1.1 x FLA
|
(6) - MCA/MFA: MCA = 1.1 x FLA
|
(6) - MCA/MFA: MCA = 1.1 x FLA
|
(6) - MCA/MFA: MCA = 1.1 x FLA
|
|
(7) - Instead of a fuse, use a circuit breaker
|
(7) - Instead of a fuse, use a circuit breaker
|
(7) - Instead of a fuse, use a circuit breaker
|
(7) - Instead of a fuse, use a circuit breaker
|
(7) - Instead of a fuse, use a circuit breaker
|
(7) - Instead of a fuse, use a circuit breaker
|
(7) - Instead of a fuse, use a circuit breaker
|
|
(8) - Select wire size based on the value of MCA
|
(8) - Select wire size based on the value of MCA
|
(8) - Select wire size based on the value of MCA
|
(8) - Select wire size based on the value of MCA
|
(8) - Select wire size based on the value of MCA
|
(8) - Select wire size based on the value of MCA
|
(8) - Select wire size based on the value of MCA
|
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|